Soakaway Testing
BRE Digest 365 Soakaway and BS6297 Percolation Testing, Devon To assist with planning for the redevelopment of a single residential property SWG undertook Soakaway testing in accordance with BRE Digest 635 for storm water drainage design and Percolation testing in accordance with BS6297 for septic tank soakaway design. It was a small side and so a small tracked excavator was used to access the site. Unfortunately the very low permeability clayey ground meant that soakaways were not suitable this time and an alternative drainage strategy was required.
1520604487000
Ground Gas Desk Study
Phase 1 Ground Gas Desk Study for redevelopment of a residential property Following submission of a Planning Application, the Local Authority expressed concern about a former quarry being a potential source of ground gas which could impact the proposed development. SWG undertook a Phase 1 contamination desk study and walkover survey to assist with planning conditions to and to produce a Conceptual Model of the site and identify the Source-Pathway-Receptor linkages between the quarry (source) and the proposed dwelling (receptor). The old quarries and associated pond located 25m south west of the site have been backfilled, in part, therefore, these features presented a theoretical source of ground gas. It was determined that as the quarries are not capped, any gasses generated would vent to the atmosphere rather than migrating laterally through the ground towards the development site. SWG argued that the use of modern construction techniques and a damp proof membrane with good sealing around pipes and floor structure will provide inherent gas protection measures. The desk study was accepted by the Local Authority and relevant warranty providers, subsequently planning was granted, saving the Client time and money.
1520602284000
Desk Study
Phase 1 desk study for conversion of barn to residential property SWG undertook a Phase 1 contamination desk study and walkover survey to assist with planning conditions to identify any potential contamination on a small a small barn site that is to be converted in to a residential dwelling. A series of historic maps were reviewed along with information on industrial land use, landfills, radon and subsidence. A conceptual model was developed which did not identify any significant sources of contamination. On this basis SWG recommended the ground suitable for use for a residential property without the need for a Phase 2 contamination investigation. The desk study was accepted by the Local Authority and relevant warranty providers, subsequently planning was granted, saving the Client time and money.
1520601502000
Coal Workings
Investigation for industrial development above known coal workings, Bristol SWG undertook an investigation to assist with the purchase of an industrial estate in Bristol. The Client wanted to understand the risks associated with former coal workings beneath the site. SWG undertook a series of rotary cored boreholes with our very own Commachio 205 drilling rig to identify where coal seams has been worked. SWG produced a cross section through the site identifying areas of known workings and provided the client with advice on foundation design and recommendations, plus preliminary costs for remediation works for the future development.
Comprehensive Site Investigation Services
Welcome to South West Geotechnical - an independent consultancy, contractor and UKAS accredited laboratory providing comprehensive ground investigation services.
PROJECTS
UKAS accredited in-situ and laboratory geotechnical testing services in the South West of England. Weekly collections and prompt turnarounds.
.
LABORATORY TESTING
Welcome to South West Geotechnical - an independent consultancy, contractor and UKAS accredited laboratory providing comprehensive ground investigation services.